FLUKE 754 / DPCTRACK2 BUNDLE A COMPLETE DOCUMENTING CALIBRATION SOLUTION
. Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
. Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
. Power transmitters during test using loop supply with simultaneous mA measurement
. Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
. Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
. Holds up to a full week of downloaded procedures and calibration results.
. Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
. Easy to use
. Three year warranty
. Bright white dual display. Read both sourced and measured parameters simultaneously.
. Multi lingual interface
. Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
. Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
. Delivered with DPC/Track Sample software.
. Compatible with many Asset Management software packages.
The Fluke 754 has features we know you'll love: increased accuracy, enhanced reliability, and is easier to read in dark environments.
HART CAPABILITIES
The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers the communication capabilities of the 375 HART communicator.
. Requires no external box or second tool for everyday HART calibration and maintenance.
. Offers fast HART communication.
. Supports popular models of HART transmitters, with more devise-specific command support than any other HART field calibrator.
. Works with multiple masters, burst mode, and multi-drop configurations.
. Is easy to update as additional instruments are added and new HART versions are released.
. Interrogate to determine device type, manufacturer, model, tag.
. Reconfigure the sensor mapping of dual sensor temperature transmitters.
. Read HART PV function and smart transmitter digital output while measuring analog mA output.
. Read and write HART configuration functions to make field adjustments to PV range points, damping, and other top-level configuration settings.
. Re-label smart transmitters by reading and writing to the HART tag field.
-----------------------------------------
Keywords: Fluke Process Calibration Tools