Prova CM-02

PROVA CM-02 AC/DC CLAMP METER (CELSIUS)


PROVA CM-02 AC/DC CLAMP METER (CELSIUS)
375,00 $


Primo number :*PRCM02-C
Brand :Prova
Brand number :CM-02




Disponibility
In stock

Quantity :



1-888-774-6665 Need help? Contact us 1-888-774-6665


PROVA CM-02 AC/DC CLAMP METER • DC/AC 0.01A Resolution • 23mm Jaw Diameter • Temperature and Capacitance • Autorange V Hz °C °F –| |– • AC/DC 0.01A-200A • One Touch Zero • 3-3/4 Digits (4000 Counts) • Max/Min/Hold/Relative • IEC 1010 CAT. II 600V General Specification: Conductor Size: 23mm Diameter Battery: 1.5V AA UM3 battery x 2 Display: 3-3/4 Digits (4000 Counts) Range Selection: Auto and Manual Power Consumption: 10mA (Approx.) Sampling Time: 2 Times/Sec. (Digital), 20 Times/Sec. (Bar-Graph) Operating Temperature: 0 to 50°C (32 to 122°F) Operating Humidity: Less than 85% RH Dimension: 183mm(L) x 63.6mm(W) x 35.6mm(H) 7.2”(L) x 2.5”(W) x 1.4”(H) Weight: 190g (Batteries included) Electrical Specification (23°C ± 5°C) DC Current Range: 40A/0-150A/150-200A Resolution: 10mA/0.1A Accuracy: ± 1.5% ± 2 dgts/± 1.5% ± 3 dgts Overload Protection: 400A AC Current Range: 40A/0-150A/150-200A Resolution: 10mA/0.1A Accuracy: ± 1.5% ± 3 dgts/ ± 2.0% ± 3 dgts (50/60Hz) ± 2.5% ± 3 dgts/± 3.0% ± 3 dgts (40-1KHz) Overload Protection: 400A DC Voltage (Autorange & Manual, Overload Protection 800VAC): Range: 400mV/4V/40V/400V/600V Resolution: 0.1mV/0.001V/0.01V/0.1V/1V Accuracy: ± 1.5% ± 3 dgts Overload Protection: 10MO/5MO AC Voltage (Autorange & Manual, Input Impedance 5MO) Range: 4V/40V/400V/600V Resolution: 0.001V/0.01V/0.1V/1V Accuracy: ± 1.5% ± 5 dgts Overload Protection: 800VAC Frequency (Hz, Autorange & Sensitivity selected by RANGE button): Range: 100~1000KHz Resolution: 0.01~100Hz Accuracy: ± 0.5% ± 2 dgts Sensitivity: 10mV/0.1V/1V Overload Protection: 600VAC Resistance (Ohm) & Audible Continuity (Open Circuit Voltage 0.5V): Range: 40~400 O Resolution: 0.1 O Accuracy: ± 1.0% ± 5 dgts Beeper: <= 40 O (approx.) Overload Protection: 600VAC Resistance (Ohm) (Autorange & Manual, Open Circuit Voltage <=0.5V): Range: 400 O/4K O/40K O/400KO/4MO/40MO Resolution: 0.1O/1 O/10 O/100 O/1KO/10KO Accuracy: ± 1.5% ± 3 dgts Overload Protection: 600VAC Capacitance (Autorange & Manual): Range: 4nF/40nF/400nF/4uF/40uF Resolution: 1pF/10pF/0.1nF/1nF/10nF Accuracy: ± 5.0% ± 0.2nF/± 3.0% ± 0.2nF/ ± 3.0% ± 0.002uF Overload Protection: 600VAC TEMP K TYPE °C (Autorange & Manual, °F optional): Range: -40~0°C/0~400°C/400~1000°C Resolution: 0.1°C/1°C Accuracy: ± 2.0% ± 2°C/± 0.5% ± 1°C/ Sensitivity: ± 0.8% ± 1°C Overload Protection: 600VAC/600V


Accepted payment methods
Visa MasterCard

General terms and conditions
including shipping and delivery
Shipping and delivery

1-888-774-6665
Speak free with one of our advisors


facebook google + youtube linkedin