Megger MJ359


Contact us for pricing and availability


Primo number :ME6410-865
Brand :Megger
Brand number :MJ359











1-888-774-6665 Contact us 1-888-774-6665


MEGGER MJ359 INSULATION RESISTANCE TESTER . No scale multipliers . Multiple test voltages for spot and step voltage testing . Guard terminal to eliminate surface leakage current Quality is crafted into every Major MEGGER Insulation Tester, with excellent test voltage regulation, direct measurement readout and an external guard terminal to eliminate surface leakage current from the measurement. Five models are available for general purpose testing which include a low-voltage model. All are portable, self-contained instruments designed to give rapid and accurate measurements. Four of the models feature an analog display having four selectable test voltages of 100, 250, 500 and 1000 Vdc, measuring insulation resistance up to 2000 MO, and an ohm range to 5000O. The other model has four test voltages of 50, 100, 250 and 500 Vdc measuring insulation resistance up to 1000 MO. The only other difference between the five analog models is the type of power source. Power for models MJ159 and MJ160 is derived from a low-voltage, hand cranked generator which has been designed to be easy to turn even under full load conditions. The low-voltage generator is connected to an electronic inverter to provide a very stable test voltage. Accuracy of measurement is unaffected by variations in the generator cranking speed and the test voltage is maintained at its rated value. Power for model MJ359 is provided by 120 V ac 50/60 Hz or low-voltage generator. Model MJ559 is also 120 Vac 50/60 Hz or internal rechargeable batteries and model MJ459 is powered by 6 replaceable AA alkaline cells. As a safety feature, the ac voltage range becomes effective as soon as the instrument is connected to the circuit under test. Therefore, a warning is given that the circuit under test is not de-energized before the instrument is operated. Though calibrated for ac voltage, this range also monitors the automatic discharge feature so that after equipment having capacitance (i.e. a cable), has been tested, an indication can be given that the voltage has discharged to a level that is safe for removing the test leads. Each instrument has a guard terminal which may be used to prevent the effects of surface leakage from influencing the readings. This is achieved by diverting the leakage current through the guard terminal and away from the instrument?s measuring circuit. Each instrument is built into a strong ABS plastic case with a fold down carrying handle


Accepted payment methods
Visa MasterCard

General terms and conditions
including shipping and delivery
Shipping and delivery

1-888-774-6665
Speak free with one of our advisors