Prostat CPM-760A

PROSTAT CPM-760A 6" CHARGE PLATE MONITOR ASSEMBLY


PROSTAT CPM-760A 6" CHARGE PLATE MONITOR ASSEMBLY
1 353,00 $


Primo number :PRCPM-760A
Brand :Prostat
Brand number :CPM-760A




Disponibility
Call us for availability

Quantity :



1-888-774-6665 Need help? Contact us 1-888-774-6665


PROSTAT CPM-760A 6" CHARGE PLATE MONITOR ASSEMBLY Collapsible for easy, compact storage •The CPM-760A is a 20pF, 6-inch Charge Plate Monitor assembly intended for use with the PFM-711A Field Meter, PCS-730 Charging Source and PDT-740B Static Decay Timer. • Designed to perform very accurate performance audits on overhead ionizers and room ionization systems. • Used with extension wings, the CPM-760A is also used to evaluate and balance bench top ionizers. • Completely collapsible for compact storage. The CPM-760A is a 20pF, 6-inch Charge Plate Monitor assembly intended for use with the Prostat PFM-711A Field Meter, PCS-730 Charging Source and PDT-740B Static Decay Timer. This handy accessory is designed to perform very accurate performance audits on overhead ionizers and room ionization systems. Used with extension wings, the CPM-760A is also used to evaluate and balance bench top ionizers. The CPM-760A is completely collapsible for compact storage in the Prostat Professional ESD Auditing Kit Series. It may be used for evaluating voltage generation and static decay performance of personnel, footwear, flooring, chairs, carts and other equipment and materials. Technical Specifications ISOLATED PLATE : Electro-plated Aluminum plate, 6.0 inches square. GROUND PLATE : Plated aluminum sheet, 6.0 inches square. PLATE SPACING : Approximately 0.63 inches between Isolated and Ground plates. Plate spacers made from machined virgin, white Teflon® Rod SUPPORT : Stored disassembled, plated aluminum sheet and steel lower stabilizing block. ASSEMBLY : Assembled with machine cap screws. CAPACITANCE : Parallel Plate Capacitance 20 picofarads (pF) ± 2 pF RANGE: 0 to ± >5 kV at a plate separation of 0.63 inch. ACCURACY : ± 2% 0 to 1,000 volts. 5 MINUTE DECAY @ 50% RH : When charged to 1kV, floating plate voltage decays less than 5% (<50 volts) over a 5 minute period. CALIBRATION : Accomplished via adjustable instrument saddle and grounding device. GROUNDING : Via snap fastener of Model PFM-711A and meter saddle assembly. ASSEMBLY : 6.0" High in Vertical Test Configuration HEIGHT : 9.0" High in Horizontal Test Configuration; Center of Plate 6.0" from Worksurface WEIGHT : 2.5 pounds


Accepted payment methods
Visa MasterCard

General terms and conditions
including shipping and delivery
Shipping and delivery

1-888-774-6665
Speak free with one of our advisors


facebook google + youtube linkedin